erä Korin pohja nro | Tyyppi | Tulostusmomentti (Nm) | Lähtökierrosnopeus (r / min) | Moottorin parametrit (kolmivaiheinen) | 90 ° Täysi matka-aika (S) | Perusmallin paino (kg) | |
Vertailuteho (KW) | Nimellisteho (A) | ||||||
SLP30 | SLP5-l | 50 | 1,0 | 0,04 | 0,26 | 15,0 | 23 |
SLP10-1 | 100 | 0,06 | 0,40 | ||||
SLP15-1 | 150 | 0.09 | 0,60 | ||||
SLP20-1 | 200 | 0.09 | 0,60 | ||||
SLP30-1 | 300 | 0.12 | 0.70 | ||||
SLP90 | SLP40-0.5 | 400 | 0,50 | 0.09 | 0,60 | 30.0 | 42 |
SLP40-1 | 1,0 | 0,18 | 0.95 | 15,0 | |||
SLP60-0.5 | 600 | 0,50 | 0.12 | 0.70 | 30.0 | ||
SLP60-1 | 1,0 | 0,18 | 0.95 | 15,0 | |||
SLP90-0.5 | 900 | 0,50 | 0,18 | 0.95 | 30.0 | ||
SLP90-1 | 1,0 | 0,25 | 1.30 | 15,0 | 56 | ||
SLP120 | SLP100-0.5 | 1000 | 0,50 | 0,25 | 1.30 | 30.0 | |
SLP100-1 | 1,0 | 0,37 | 1.60 | 15,0 | |||
SLP120-0.5 | 1200 | 0,50 | 0,25 | 1.30 | 30.0 | ||
SLP120-1 | 1,0 | 0,37 | 1.60 | 15,0 | |||
SLP300 | SLP200-0.5 | 2000 | 0,50 | 0,37 | 1.60 | 30.0 | 70 |
SLP200-1 | 1,0 | 0,55 | 1.40 | 15,0 | |||
SLP250-0.5 | 2500 | 0,50 | 0,37 | 1.60 | 30.0 | ||
SLP250-1 | 1,0 | 0,55 | 2,40 | 15,0 | |||
SLP300-0.5 | 3000 | 0,50 | 0,55 | 1.40 | 30.0 | ||
SLP800 | SLP400-0.25 | 4000 | 0,25 | 0,37 | 1.60 | 60.0 | 145 |
SLP400-0.5 | 0,50 | 0,55 | 2,40 | 30.0 | |||
SLP600-0.25 | 6000 | 0,25 | 0,55 | 2,40 | 60.0 | ||
SLP600-0.5 | 0,50 | 1.10 | 3,40 | 30.0 | |||
SLP800-0.25 | 8000 | 0,25 | 1.10 | 3,40 | 60.0 | ||
SLP1600 | SLP800-0.5 | 10000 | 0,50 | 1,50 | 4.50 | 30.0 | 220 |
SLP1000-0.3 | 12000 | 0,30 | 1,50 | 4.50 | 50,0 | ||
SLP1200-0.3 | 0,30 | 1,50 | 4.50 | 50,0 | |||
SLP1600-0.2 | 16000 | 0,20 | 1,50 | 4.50 | 75.0 | ||
Huomautuksia: Tämä arkki sisältää vain 380V: n kolmivaihemoottorin parametrit. Moottorin estovirran ja nimellisvirran välisen suhteen takuuarvo on 7 nimellisjännitettä. Korvaus on 20% takuuarvosta. Kun tuote on yksivaiheinen, tuotteen asiakirjojen ja lähetysmerkin parametrit.
Suositut Tagit: osittain käänteinen perhosventtiilin toimilaite, Kiina, valmistajat, toimittajat, tehdas, osto, hinta, tarjous
SLP30, SLP90 ja SLP30L, SLP90L määrityskaavio (perusmalli ja yleinen paikallinen malli)

SLP30, SLP90 ja SLP30L, SLP90L-kokoonpanon mitat
| B | C | D | E | F | G | H | minä | J | |
SLP30 | 55 | 270 (MAX) | 188 | Ф200 | Ф180 | Ф125 | 65 | 260 | 84 | ≈80 |
SLP30L | ||||||||||
SLP90 | 75 | 35 (MAX) | 205 | Ф250 | Ф202 | Ф175 | 87 | 287 | 98.5 | ≈110 |
SLP90L | ||||||||||
K | L | M | N | O | P | Q | R | S | T | |
SLP30 | 65 | 65 | Ф102 | Ф116 | ≈138 | 65 | ||||
SLP30L | 145 | 215 | ||||||||
SLP90 | 87 | 87 | Ф124 | Ф130 | ≈160 | 85 | ||||
SLP90L | 160 | 230 |
SLP120 ~ SLP1600 ja SLP120L ~ SLPl600L-määrityskaavio (perusmalli ja yleinen paikallinen malli)

SLP120 ~ SLP1600 ja SLP120L ~ SLP 1600L: n kokoonpanon mitat
| B | C | D | E | F | G | H | minä | J | |
SLP120 | 103 | 360 (MAX) | 175 | Ф250 | Ф202 | Ф235 | 115 | 325 | 130 | 160 |
SLP120L | ||||||||||
SLP300 | 117 | 370 (MAX) | 200 | Ф300 | Ф202 | Ф270 | 134 | 352 | 157 | 175 |
SLP300L | ||||||||||
SLP800 | 134 | 460 (MAX) | 265 | Ф600 | Ф220 | Ф310 | 162/181 | 410/429 | 206/225 | 200 |
SLP800L | ||||||||||
SLP1600 | 134 | 480 (MAX) | 265 | Ф600 | Ф220 | Ф440 | 230 | 530 | 293 | 270 |
SLP1600L | ||||||||||
K | L | M | N | O | P | Q | R | S | T | |
SLP120 | 66 | 140 | 25 | 82 | Ф124 | Ф130 | ≈210 | 85 | ||
SLP120L | 205 | 275 | ||||||||
SLP300 | 70 | 117 | 25 | 106 | Ф124 | Ф130 | ≈230 | 120 | ||
SLP300L | 215 | 285 | ||||||||
SLP800 | 85 | 225/244 | 37 | 126/145 | Ф165 | ≈250 | ||||
SLP800L | 250 | 320 | ||||||||
SLP1600 | 165 | 293 | 37 | 64 | Ф165 | ≈250 | ||||
SLP1600L | 250 | 320 |
Huomautuksia: Fraktiotietojen osalta lukija on alle 6000N.m (sisältäen 6000N.m) määrittelytuotteen; nimittäjä on 8000N.m eritelmätuote.
Sähköisen ohjauksen perusperiaate ja siihen liittyvä suunta

1. Tässä kaaviossa esitetty venttiili sijaitsee keskiasennossa.
2. Tämän kaavion viivapisteen rivin osat ovat sähkötoimilaitteen sisällä.
Terminaaliliitännän vertailutaulukko
Terminals | U | V | W | E | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
EI | U | V | W | E | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
15 | KH | Lämpörele |
14 | RP1 | Aseta potentiometri |
13 | STO STC | Vääntömomentin kytkin |
12 | SL1 SL2 | Aseta rajakytkin |
11 | RH | Lämmittimen vastus |
10 | HR HG HY | Merkkivalo |
9 | SS SO SC | Kauko-ohjauspainike |
8 | T | Muuntaja |
7 | R | vastus |
6 | idc | Aseta osoitinmittari |
5 | QC | Virtalähteen kytkin |
4 | RP2 | Potentiometri |
3 | FU | Sulake |
2 | KO KC | Vaihtoehtoinen virtakontaktori |
1 | M | Kolmivaiheinen asynkroninen moottori |
Ei. | Koodi | kuvaukset |
ohjeet
Yllä oleva kaavio esittää sarjan SLP-sähkötoimilaitteiden sähköisen ohjauksen perusperiaatteen, se voi suorittaa sähköventtiilin ohjauksen tavallisissa olosuhteissa. Todellisissa sovelluksissa sähköisen ohjauksen periaatteella on paljon vaatimuksia. Tarvitaan esimerkiksi lisäämään ohjaus- ja vääntömomentin ja passiivisten liittimien koskettimia, tarvitsemaan paikallista ohjauskytkintä ja paikallis- / kauko-vaihtokytkintä, edellyttäen paikallisen venttiiliasennon merkkivaloa, tarvitsevat tarkan potentiometrin ja venttiilin aseman lähettimen (VOT) toiminto, jonka sähköinen toimilaite voi vastaanottaa 4 ~ 20 mA: n signaalin jne. Joten käyttäjien tulisi ohjata vaatimukset tilattaessa. Yrityksemme tarjoaa periaatteellisen esitteen, joka koostui kaikista sähköisen ohjauksen toiminnoista käyttäjille.